5 Remote I/O Communications
Communications
mode number
3
5-40
Device variables for the CJ-series
Unit
*_OutDat00 to *_OutDat15 ((*_OutDat00_00
to *_OutDat00_15) to (*_OutDat15_00 to
*_OutDat15_15))
*_InDat00 to *_InDat15
((*_InDat00_00 to *_InDat00_15) to
(*_InDat15_00 to *_InDat15_15))
*_BitOutDat00_00 to
*_BitOutDat63_01
*_BitInDat00_00 to *_BitInDat63_01
*_UnitSta
*_UnitCmd
*_OutCnctNdSta00_07
(*_OutCnctNdSta00 to 07)
*_OutCnctNdSta08_15
(*_OutCnctNdSta08 to 15)
*_InCnctNdSta00_07
(*_InCnctNdSta00 to 07)
*_InCnctNdSta08_15
(*_InCnctNdSta08 to 15)
*_OutErrNdSta00_07
(*_OutErrNdSta00 to 07)
*_OutErrNdSta08_15
(*_OutErrNdSta08 to 15)
*_InErrNdSta00_07
(*_InErrNdSta00 to 07)
*_InErrNdSta08_15
(*_InErrNdSta08 to 15)
*_BitOutCnctNdSta00_07
(*_BitOutCnctNdSta00 to 07)
*_BitOutCnctNdSta08_15
(*_BitOutCnctNdSta08 to 15)
*_BitOutCnctNdSta16_23
(*_BitOutCnctNdSta16 to 23)
*_BitOutCnctNdSta24_31
(*_BitOutCnctNdSta24 to 31)
*_BitOutCnctNdSta32_39
(*_BitOutCnctNdSta32 to 39)
*_BitOutCnctNdSta40_47
(*_BitOutCnctNdSta40 to 47)
*_BitOutCnctNdSta48_55
(*_BitOutCnctNdSta48 to 55)
*_BitOutCnctNdSta56_63
(*_BitOutCnctNdSta56 to 63)
*_BitInCnctNdSta00_07
(*_BitInCnctNdSta00 to 07)
*_BitInCnctNdSta08_15
(*_BitInCnctNdSta08 to 15)
*_BitInCnctNdSta16_23
(*_BitInCnctNdSta16 to 23)
*_BitInCnctNdSta24_31
(*_BitInCnctNdSta24 to 31)
CJ-series CompoNet Master Unit Operation Manual for NJ-series CPU Unit (Cat. No. W493)
Pattern
Slave Unit I/O data
WORD OUT Data (16 words): Word Slave Unit outputs
00 to 15
WORD IN Data (16 words): Word Slave Unit inputs 00 to
15
BitOUT Data (8 words): Bit Slave Unit outputs 00 to 63
BitIN Data (8 words): Bit Slave Unit inputs 00 to 63
Status (1 word)
Settings (1 word)
WORD OUT Connect Flags:
Word Slave Unit outputs 00 to 07 (BYTE)
Word Slave Unit outputs 08 to 15 (BYTE)
WORD IN Connect Flags:
Word Slave Unit inputs 00 to 07 (BYTE)
Word Slave Unit inputs 08 to 15 (BYTE)
WORD OUT Communication Error Flags:
Word Slave Unit outputs 00 to 07 (BYTE)
Word Slave Unit outputs 08 to 15 (BYTE)
WORD IN Communication Error Flags:
Word Slave Unit inputs 00 to 07 (BYTE)
Word Slave Unit inputs 08 to 15 (BYTE)
BIT OUT Connect Flags:
Bit Slave Unit outputs 00 to 07 (BYTE)
Bit Slave Unit outputs 08 to 15 (BYTE)
Bit Slave Unit outputs 16 to 23 (BYTE)
Bit Slave Unit outputs 24 to 31 (BYTE)
Bit Slave Unit outputs 32 to 39 (BYTE)
Bit Slave Unit outputs 40 to 47 (BYTE)
Bit Slave Unit outputs 48 to 55 (BYTE)
Bit Slave Unit outputs 56 to 63 (BYTE)
BIT IN Connect Flags:
Bit Slave Unit inputs 00 to 07 (BYTE)
Bit Slave Unit inputs 08 to 15 (BYTE)
Bit Slave Unit inputs 16 to 23 (BYTE)
Bit Slave Unit inputs 24 to 31 (BYTE)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)
(1
word)

Advertisement