Machine Parameter 066
Initial
Switch
Setting
7
0
Loop volume adjustment at
DRS sensor
6
0
5
0
4
0
To improve screw in URADF,
3
0
adjust this parameter.
2
0
1
0
1 step = 2 / 600 dpi
0
0
Machine Parameter 067 ~ 259 — Factory use only
Adjust
(0.084 mm)
Usage/Comments
Increasing this value may improve document skew
but lead to noise or damage to document.
Decreasing this value may improve noise or dam-
age to document but document may not be fed
normally.
Switch
76543210
127 steps 01111111
:
00100000
:
00010000
:
00001000
:
00000000
:
10001000
:
10010000
:
10100000
:
-127steps
11111111
3-14
Settings
+10.67 mm
+2.69 mm
+1.34 mm
+0.67 mm
0 mm
-0.67 mm
-1.34 mm
-2.69 mm
-10.67 mm