Memory switch 01x : Transmission
Memory switch 015 :
Initial
bit
Setting
7
0
Program individual autodi-
aler attributes
0 : No
1 : Yes
6
0
Factory use only
5
0
Factory use only
4
0
Factory use only
3
0
Factory use only
2
0
Sending RTC signal when
transmission is canceled
0 : Yes
1 : No
1
1
Cancel redial if T.4.1 or
T.4.4 error occurs
0 : Yes
1 : No
0
1
Action after EOR signal
0 : Continue
1 : Discontinue
Memory switch 016 :
Initial
bit
Setting
7
0
Factory use only
6
0
Factory use only
5
0
Factory use only
4
0
Disable DCS -bit 44 at Fine
and Normal transmission
0: Enable
1: Disable
3
1
A d d i t i o n a l d a t a o n T T I
transmit
0 : No
1 : Yes
2
1
Subscriber ID transmit
0 : No
1 : Yes
1
1
TTI (name) transmit
0 : No
1 : Yes
0
0
Factory use only
Adjust
Allows individual setting of memory switches 010 as attribute
1, 011 as attribute 2, 012 as attribute 3 and 013 as attribute 4
when fax destination are programmed. (Refer to page 3-54 for
settings.)
RTC signal is sent at the end of the transmission.
When set at "0", the machine will send the RTC if the transmis-
sion is canceled. No error will occur.
When set at "1", an error will occur because RTC will not be
sent at the end of a canceled transmission.
When set at "0", if a T.4.1 or T.4.4 error occurs, the machine
will not retry the transmission.
Sets action after receiving PPR four times at 2400 bps.
Adjust
This avoid a trouble that a PC-FAX stretches to the vertical
direction when the other party has received it.
Use only when trouble has occurred.
When set at "0", the transmission of the additional data (time,
the number of pages, file number, etc) is disabled.
NOTE
This switch is available only when Memory switch 012, bit
4 and/or Memory switch 013, bit 5 is available.
When set at "0", the transmission of the subscriber ID is dis-
abled.
NOTE
This switch is available only when Memory switch 012, bit
4 and/or Memory switch 013, bit 5 is available.
When set at "0", the transmission of the name which was
stored in the unit is disabled.
NOTE
This switch is available only when Memory switch 012, bit
4 and/or Memory switch 013, bit 5 is available.
Usage / Comments