Operating variable 
[0] None (No display value) 
P 0‐15 Readout: actual setup 
P 0‐37 Display Text 1 
P 0‐38 Display Text 2 
P 0‐39 Display Text 3 
P 0‐89 Date and Time Readout 
P 13‐97 Alert Alarm Word 
P 13‐98 Alert Warning Word 
P 13‐99 Alert Status Word 
P 15‐00 Operating hours 
P 15‐01 Running Hours 
P 15‐02 kWh Counter 
P 15‐80 Fan Running Hours 
P 16‐00 Control Word 
P 16‐01 Reference 
P 16‐02 Reference 
P 16‐03 Status Word 
P 16‐05 Main Actual Value 
P 16‐09 Custom Readout 
P 16‐10 Power 
P 16‐11 Power 
P 16‐12 Motor Voltage 
P 16‐13 Frequency 
P 16‐14 Motor Current 
P 16‐15 Frequency 
P 16‐16 Torque 
P 16‐17 Speed 
P 16‐18 Motor Thermal 
P 16‐19 Thermistor Sensor Temp 
P 16‐20 Motor Angle 
P 16‐22 Torque 
P 16‐23 Motor Shaft Power 
P 16‐24 Calibrated Stator Resistance 
P 16‐26 Power Filtered 
P 16‐27 Power Filtered 
P 16‐30 DC Link Voltage 
P 16‐32 Brake Energy /s 
P 16‐33 Brake Energy Average 
P 16‐34 Heatsink Temp. 
P 16‐35 Inverter Thermal 
P 16‐36 Inv. Nom. Current 
P 16‐37 Inv. Max. Current 
P 16‐38 SL Controller State 
P 16‐39 Control Card Temp. 
P 16‐42 Service Log Counter 
P 16‐43 Timed Actions Status 
P 16‐45 Motor Phase U Current 
P 16‐46 Motor Phase V Current 
P 16‐47 Motor Phase W Current 
P 16‐50 External Reference 
P 16‐52 Feedback 
 
 
These variables can be viewed temporarily using the given read‐only parameters shown in the 
chart above or set up on the display in the Operation / Display (P 0‐2*) menu group. 
 
Available LCP Display Variables 
 
 
 
Unit 
 
  
 
  
 
  
 
  
 
  
 
  
 
  
 
  
 
  
 
 
 
kWh 
 
 
hex 
 
Unit 
 
 
hex 
 
 
Unit 
 
kW 
 
hp 
 
 
Hz 
 
 
 
Nm 
 
RPM 
 
 
 °C 
 
  
 
 
kW 
 
Ohm 
 
kW 
 
hp 
 
 
kW 
 
kW 
 
°C 
 
 
 
 
  
 
°C 
 
  
 
  
 
 
A  
 
A  
 
  
 
Unit 
 
2
Operating variable 
P 16‐53 Digi Pot Reference 
P 16‐54 Feedback 1 
P 16‐55 Feedback 2 
P 16‐56 Feedback 3 
P 16‐58 PID Output 
P 16‐59 Adjusted Setpoint 
P 16‐60 Digital Input 
P 16‐61 Terminal 53 Switch Setting 
P 16‐62 Analog Input 53 
P 16‐63 Terminal 54 Switch Setting 
P 16‐64 Analog Input 54 
P 16‐65 Analog Output 42 
P 16‐66 Digital Output 
P 16‐67 Pulse Input #29 
P 16‐68 Pulse Input #33 
P 16‐69 Pulse Output #27 
P 16‐70 Pulse Output #29 
P 16‐71 Relay Output 
P 16‐72 Counter A 
P 16‐73 Counter B 
P 16‐80 Fieldbus CTW 1 
P 16‐82 Fieldbus REF 1 
P 16‐84 Comm. Option STW 
P 16‐85 FC Port CTW 1 
P 16‐86 FC Port REF 1 
P 16‐87 Bus Readout Alarm/Warning 
P 16‐90 Alarm Word 
P 16‐91 Alarm Word 2 
P 16‐92 Warning Word 
P 16‐93 Warning Word 2 
P 16‐94 Ext. Status Word 
P 16‐95 Ext. Status Word 2 
P 16‐96 Maintenance Word 
P 16‐97 Alarm Word 3 
P 16‐98 Warning Word 3 
P 18‐50 Sensorless Readout 
P 18‐57 Air Pressure to Flow Air Flow 
P 18‐60 Digital Input 2 
P 21‐17 Ext. 1 Reference 
P 21‐18 Ext. 1 Feedback 
P 21‐19 Ext. 1 Output 
P 21‐37 Ext. 2 Reference 
P 21‐38 Ext. 2 Feedback 
P 21‐39 Ext. 2 Output 
P 21‐57 Ext. 3 Reference 
P 21‐58 Ext. 3 Feedback 
P 21‐59 Ext. 3 Output 
P 22‐30 No‐Flow Power 
P 23‐16 Maintenance Text 
P 25‐80 Cascade Status 
P 25‐81 Pump Status 
Unit 
  
Unit 
Unit 
Unit 
 % 
bin 
  
mA or V 
  
mA 
bin 
Hz 
Hz 
Hz 
Hz 
 bin 
  
  
hex 
hex 
hex 
hex 
hex 
hex 
hex  
hex  
hex  
hex  
hex  
hex  
hex  
hex  
hex  
Unit 
m
3
/h 
bin 
Unit 
Unit 
Unit 
Unit 
Unit 
Unit 
kW 
  
  
  