Agilent Technologies 8960 10 Series Reference Manual page 483

Wireless communications test set, gsm mobile test application
Hide thumbs Also See for 8960 10 Series:
Table of Contents

Advertisement

SYSTem:COMMunicate:LAN[:SELF]:DGATeway
Function
Sets/queries the LAN IP router/gateway address for the test set.
Setting
Range: 15 characters formatted as follows: A.B.C.D where A= 0 to 223 B,C,D = 0 to 255 (no
embedded spaces), blank field
Query
Range: 15 characters formatted as follows: A.B.C.D where A,B,C,D = 0 to 255 (no embedded
spaces). blank field
Factory
blank field, (this parameter is not affected by any reset operation)
setting
Programming Example
OUTPUT 714;"SYSTEM:COMMUNICATE:LAN:SELF:DGATEWAY '15.2.6.200'"
SYSTem:COMMunicate:LAN[:SELF]:SMASk
Function
Sets/queries the subnet mask of the test set based on the LAN IP address selected. The subnet
mask changes according to the value of A used for the LAN IP address.
If A is less than or equal to 127, the subnet mask is 255.0.0.0.
If A is greater than 127 and less or equal to 191, the subnet mask is 222.255.0.0.
If A is grater than 191, the subnet mask is 255.255.255.0.
If the LAN address is changed the subnet mask should be checked to insure that it is set to the
proper class for that LAN address.
Setting
Range: 15 characters formatted as follows: A.B.C.D where A,B,C,D are between = 0 to 255 (no
embedded spaces)
Query
Range: 15 characters formatted as follows: A.B.C.D where A,B,C,D are between = 0 to 255 (no
embedded spaces)
Factory
0.0.0.0 (this parameter is not affected by any reset operation and can only be changed by direct
setting
user access)
Programming Example
OUTPUT 714;"SYSTEM:COMMUNICATE:LAN:SELF:SMASK '15.2.6.200'"