Solar charging
Max. PV open circuit
voltage
MPPT voltage range
Max. PV input power
Max. PV charging power
Max.
PV
charging
current
Equalize charging voltage
Boost charging voltage
Float charging voltage
Low voltage disconnect
voltage
Tracking efficiency
Temp.
compensate
coefficient
General
Surge current
Zero load consumption
Standby current
Mechanical Parameters
Dimension(H x W x D)
607.5x381.6x127mm
Mounting size
Mounting hole size
30A)
450V
2500W
(Note: For the curve of Max. PV input power Vs. PV open-circuit voltage, see chapter Appendix 1 for details.)
1725W
60A
29.2V(AGM default)
28.8V(AGM default)
27.6V(AGM default)
21.6V(AGM default)
50A
<1.8A
(without PV and utility connection, turn on the load output)
<1.2A
(without PV and utility connection, turn off the load output)
642.5x381.6x149mm
585*300mm
620*300mm
Φ10mm
is 40A)
, 395V
80~350V
4000W
4000W
2875W
2875W
100A
≥99.5%
-3mV/℃/2V(Default)
60A
607.5x381.6x149mm
585*300mm
Φ10mm
Φ10mm
53
120~400V
50A
58.4V(AGM default)
57.6V(AGM default)
55.2V(AGM default)
43.2V(AGM default)
56A
<1.2A
<0.7A
642.5x381.6x149mm
620*300mm
500V
440V
4000W
4000W
80A
95A
Φ10mm

Hide quick links:

Advertisement

Table of Contents
loading