Epever UPower-HI Series User Manual page 53

Inverter/charger
Hide thumbs Also See for UPower-HI Series:
Table of Contents

Advertisement

Max. PV open circuit
voltage
MPPT voltage range
Max. PV input power
Max. PV charging power
Max.
PV
charging
current
Equalize charging voltage
Boost charging voltage
Float charging voltage
Low voltage disconnect
voltage
Tracking efficiency
Temp.
compensate
coefficient
General
Surge current
Zero load consumption
Standby current
Mechanical Parameters
Dimension(H x W x D)
Mounting size
Mounting hole size
Net Weight
At minimum operating environment temperature
2000W
(Note: For the curve of Max. PV input power Vs. PV open-circuit voltage, see chapter Appendix1 for details.)
1725W
60A
29.2V(AGM default)
28.8V(AGM default)
27.6V(AGM default)
21.6V(AGM default)
50A
<1.6A
<1.2A
607.5x381.6x127mm
585*300mm
Φ10mm
15kg
250V
, 220V
60~200V
3000W
2875W
100A
≥99.5%
-3mV/℃/2V(Default)
60A
<1.6A
(without PV and utility connection, turn on the load output)
<1.0A
(without PV and utility connection, turn off the load output)
642.5x381.6x149mm
620*300mm
Φ10mm
19kg
At 25℃ environment temperature
51
3000W
2875W
50A
58.4V(AGM default)
57.6V(AGM default)
55.2V(AGM default)
43.2V(AGM default)
56A
<1.2A
<0.7A
642.5x381.6x149mm
620*300mm
Φ10mm
19kg
4000W
4000W
80A
95A
<0.8A
<0.6A
642.5x381.6x149mm
620*300mm
Φ10mm
19kg

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents