Summary of Contents for Epever SHI2000-22-G

  • Page 1 SHI-G SERIES ——Pure Sine Wave Inverter User Manual Models: SHI2000-G/SHI3000-G...
  • Page 3 CONTENT 1 Introduction ............. 1 2 Important Safety Instructions ......3 3 Inverter Operation ........... 5 4 Functions ............7 5 Troubleshooting ..........14 6 Maintenance and Warranty ......15 7 Technical Specification ........16...
  • Page 5: Introduction

    1 Introduction Thank you for purchasing SHI series inverters. The product is a pure sine wave inverter which can convert 24/48V DC to 220/230V AC 50/60Hz based on full digital and intelligent design. It has the mains supply bypass switchover function. It features high reliability, high efficiency, concise outline, small volume, full protection functions, easy installation and operation, etc.
  • Page 6 inverter‟s inner fault identification protections. ◆ Wide working temperature range (industrial level). ◆ Continuous operation at full power.
  • Page 7: Important Safety Instructions

    2 Important Safety Instructions As an AC power supply equipment, the inverter‟s output voltage is with the same level as that of household power plug. Mind the AC output terminals, or you may get an electric shock and result in life danger! Attentions: ★...
  • Page 8 device which may suffer from high temperature when the inverter is working. Do not install the inverter in airproof location and keep enough space around the inverter. ★ The protective grounding must be connected to the ground. The cross section of wire should not be less than 4mm ★...
  • Page 9: Inverter Operation

    3 Inverter Operation Connect the input and output terminals accurately. Turn on the power using the ON / OFF switch on the front panel. In order to avoid the protections resulted from the surge power, please turn on AC loads one by one after the output of the inverter is normal. Please check it as below: ...
  • Page 10 Schematic diagram of the sysem connection AC Breaker AC 15A (SHI3000-22-G) Input Wire(Distance<3m) AC 15A (SHI3000-42-G) Mains and AC power 50mm (SHI3000-22-G) supply(220/230VAC) AC 10A (SHI2000-22-G) 25mm (SHI3000-42-G) AC 10A (SHI2000-42-G) 35mm (SHI2000-22-G) 16mm (SHI2000-42-G) Output Wire(Distance<50m) (SHI3000-22-G) (SHI3000-42-G) (SHI2000-22-G)...
  • Page 11: Functions

    4 Functions  DC Input Panel Fan Ventilation Input Positive Input Negative Protective Grounding  AC Input Panel Input Indicator RS485 Port Bypass switch Load Bypass Indicator indicator Fault Indicator Bypass input port Mode Switch ON/OFF Switch Switch Node Output Port 输入端口...
  • Page 12 NOTE: 1) It is recommended that multi stranded wire with thickness not greater than 6mm shall be used at the output port according to the requirement of the current density 4A/mm 2)When remove the connection wire, do stop the inverter and turn off the bypass switch first, then insert a pointed tool into the small hole above the port and pull out the connection wire.
  • Page 13 Flashing Flashing — — Red ON Output voltage abnormal — — Green ON Inverter output normal Bypass output or inverter — — output is OFF(normal OFF) NOTE:Above parameters are in 24V system at 25 º C, please double the values in 48V system Bypass indicator:indicator bypass input LED Status Bypass...
  • Page 14  Protections Inverter output short circuit protection: When the inverter output end is in short-circuited, the output will be stopped immediately. Then the automatic output recovery will be delayed (the first delay is a 5s time delay, the second delay is a 10s time delay and the third delay is a 15s time delay).
  • Page 15 and then restart the inverter manually. Load over than 250% will be treated as output short circuit. Bypass output overload protection: Overload >230% 125% 150% 200% Feature <0.2S Working time Auto recovery First time 5s delay; second time 10s delay; for 3 times third time 15s delay If the overload or short circuit status still remains when the inverter...
  • Page 16 When the voltage at the input end is lower than the under-voltage or overvoltage protection threshold, the output will automatically switch to the inverter output. When the voltage at the input end is higher than the under-voltage recovery threshold or lower than the overvoltage recovery threshold, the output will switch back to the bypass output.
  • Page 17 230Vac, otherwise is 220Vac. When the switch No.3 is on the ON side, the output frequency is 60Hz,otherwise is 50Hz. The inverter must stop working when it be re-set the output frequency or voltage. When the voltage level and the output frequency were set, the inverter make sure that the voltage and frequency are consistent with the bypass.
  • Page 18: Troubleshooting

    5 Troubleshooting WARNING: High voltage is inside the inverter, do not open or disassemble it! Attempting to service the unit yourself may cause the risk of electrical shock or fire! Problem Possible Cause Solution Input LED blink, Input voltage is Measure the input voltage.
  • Page 19: Maintenance And Warranty

    6 Maintenance and Warranty The casing of the inverters may be cleaned regularly with a damp cloth (not wet) to prevent accumulation of dust and dirt. The screws on the DC input terminals must be tightened. The warranty period of the inverter is 2 year since the date of original shipping.
  • Page 20: Technical Specification

    7 Technical Specification  Technical Data Types SHI2000-22-G SHI2000-42-G Nominal Battery Voltage Input Voltage 21.6 ~32Vdc 43.2 ~64Vdc Range Bypass power on 190~240Vac voltage Bypass working 176~264Vac voltage ≤0.7A(24Vdc) ≤0.45A(48Vdc) No-load current Output Voltage 220Vac± 3% / 230Vac± 10% Continuous Power...
  • Page 21 Types SHI3000-22-G SHI3000-42-G Nominal Battery Voltage Input Voltage 21.6 ~32Vdc 43.2 ~64Vdc Range Bypass power on 190~240Vac voltage Bypass working 176~264Vac voltage ≤1.0A(24Vdc) ≤0.7A(48Vdc) No-load current Output Voltage 220Vac± 3% / 230Vac± 10% Continuous Power 3000VA Power 10 sec 4500VA Output way Single phase Output wave...
  • Page 22  Environmental Parameters Working Temperature -20℃~ +50℃ Storage Temperature -35℃~ +70℃ Humidity < 95%(N.C.) < 5000m(Derating to operate according to Altitude GB 7260 a height exceeding 1000 m)  Others Between DC input terminals and metal case: ≥550MΩ; Insulation Between AC output terminals and metal case: ≥550MΩ. Resistance Between DC input terminals and metal case: Dielectric...
  • Page 24 BEIJING EPSOLAR TECHNOLOGY CO., LTD. Tel: +86-10-82894112 / 82894962 Fax: +86-10-82894882 E-mail:info@epsolarpv.com Website: http://www.epsolarpv.com/ http://www.epever.com/...