Epever UPower-HI Series User Manual page 13

Inverter/charger
Hide thumbs Also See for UPower-HI Series:
Table of Contents

Advertisement

User manual 1ps
Included accessories 1pcs(Details refer to the "Accessories list" file shipped with the
inverter/charger.)
2.2.2 Prepare modules
1)
Battery
Recommended wire size of the battery and the circuit breaker is as below.
Model
UP2000-HM6021
UP2000-HM6022
UP3000-HM5041
UP3000-HM5042
UP3000-HM8041
UP3000-HM10021
UP3000-HM10022
UP5000-HM8042
Making the battery connection wire
Step1: Ring terminal 2pcs (included accessories).
Step2: Battery positive and negative connection wires 2 pcs(red +, black -). The wire length is
determined according to the customer's actual requirement.
Step3: Strip one end of the battery connection wire for about d mm (size d is determined according to
the ring terminal).
Step4: Pass the exposed wire through the ring terminal, and secure the wire firmly with a wire clamp.
2)
AC Load
Recommended wire size of the AC load and the circuit breaker is as below.
Model
UP2000-HM6021
UP2000-HM6022
UP3000-HM5041
UP3000-HM5042
UP3000-HM8041
UP3000-HM10021
UP3000-HM10022
UP5000-HM8042
Battery wire size
2
20mm
/4AWG
2
20mm
/4AWG
2
16mm
/5AWG
2
16mm
/5AWG
2
16mm
/5AWG
2
35mm
/1AWG
2
35mm
/1AWG
2
35mm
/1AWG
Load wire size
2
6mm
/9AWG
2
3.4mm
/12AWG
2
6mm
/9AWG
2
4mm
/11AWG
2
6mm
/9AWG
2
6mm
/9AWG
2
4mm
/11AWG
2
6mm
/9AWG
11
Circuit breaker
2P—125A
2P—125A
2P—100A
2P—100A
2P—100A
2P—200A
2P—200A
2P—200A
Circuit breaker
2P—40A
2P—16A
2P—40A
2P—25A
2P—40A
2P—40A
2P—25A
2P—40A
Ring terminal
RNB38-8S
RNB38-8S
RNB22-8
RNB22-8
RNB22-8
RNB38-8S
RNB38-8S
RNB38-8S
Torque
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M
1.2N.M