System Disposal - Will Burt Night Scan Powerlite Operating Instructions Manual

Table of Contents

Advertisement

NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
that it rotates down toward the upper photo sensor (see Figure 7-4). As you approach the
sensor, watch the controller. As soon as the "Tilt Down" LED goes out, stop rotating the ring
and tighten the set screw. This should be roughly 80% penetration into the sensor with the
flag. Repeat for the other tilt shaft.
6. To set the Pan Home Position, turn the flag counterclockwise (looking from above the RCP)
until the "Pan Right" LED goes out (see Figure 7-4). Tighten the adjustment screws to secure
the ring.
7. Tilt the unit until the second set screw for the tilt flag is accessible. Tighten the second set
screw.
8. Stow the mast, watching for the RCP and lights to become oriented as described in the
beginning of this section. If it does not look like the RCP is properly positioned during
stowing, use the Emergency Stop to stop motion and re-adjust the flags.
9. Once proper positioning is achieved, raise the mast high enough and replace the RCP cover.
Tilt Sensor Home
Approach this photo sensor from this direction
Approach this photo sensor from this direction
7.7

System Disposal

Dispose of the Mast in accordance with the national environmental regulations.
PAGE 64 OF 98
Figure 7-4 RCP PCB Photo Sensors
Flag in Stowed
Position (3 places)
TP-4723701-U
MAY 2021

Advertisement

Table of Contents
loading

Table of Contents