NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
Saddle
Wiring/Air Access Panel
Figure 3-7 Above: Night Scan Powerlite, Night Scan Powerlite Xtreme, and Night Scan Powerlite
HDT Components (Left Cover Removed); Below: Night Scan Powerlite with Profiler Parts
Exhaust
Safety Valves
Figure 3-8 Night Scan Powerlite, Night Scan Powerlite Xtreme, and Night Scan Powerlite HDT
90° Limit Switch: This limit switch activates when the mast reaches the 90° vertical position.
The mast is driven into a rubber pad under the mast. It is activated by a magnet located on the tilt
mechanism. The lights and RCP functions are disabled until this 90° limit switch is activated.
Once activated, the RCP and lights are active for use. The limit switch is adjustable and set at the
factory. See Section 7.5.2 for optional adjustment procedure.
TP-4723701-U
MAY 2021
Base Board
Electrical Ground Bar
Stowed Limit Switch
Air Control Valve Assembly
Components (Left Cover Removed)
OPERATING INSTRUCTIONS
Look-Up Light
90° Limit Switch
Mast Safety Valve
PAGE 21 OF 98