Table 9-2 Error and Warning Codes for RCP (Continued)
Message
2,11
Right Tilt Up wrap
around
2,12
Right Tilt Down wrap
around
2,13
Pan Right wrap around
2,14
Pan Left wrap around
2,15
Left Tilt Limit Overlap
2,16
Right Tilt Limit Overlap
Message
WRN 3,02
Dual HHRC
simultaneous inputs
TP-4723701-U
MAY 2021
Meaning
The software indicates
the same photosensor
was made before the
opposite limit
photosensor was made
to stop rotation. This
indicates wrap around
The software indicates
the same photo sensor
was made before the
opposite limit photo
sensor was made to
stop rotation. This
indicates wrap around
The software indicates
both tilt photo sensors
appear to be blocked
simultaneously
Table 9-3 Error and Warning Codes for HHRC
Meaning
Two HHRCs are sending
commands
simultaneously.
If commands are not
conflicting, they will be
allowed (Base Board
decides).
If commands are
conflicting, no action/
movement will be
allowed by the Base
Board.
Warning appears
regardless of conflicting
or not conflicting to alert
operators that someone
else is trying to operate
the unit simultaneously
OPERATING INSTRUCTIONS
Root Issue
1. The flag that
interrupts the light may
need to be adjusted to
go deeper into the
photocell.
2. The limit photo sensor
is defective
The limit photo sensor is
defective
Foreign material in one
of the photo sensors or
faulty photo sensor
Root Issue
Multiple users
controlling the mast
Potential Cause
Potential Cause