OPERATING INSTRUCTIONS
6. Press each "Light" button several times to turn the lights on and off.
7. Press "Tilt-Up" and "Tilt-Down" buttons one at a time. Press "Pan-Left" and "Pan-Right"
buttons one at a time. Check the lights again.
8. Press and hold the "Mast-Up" button. When the mast is fully extended and the blow-off valve
opens, release the "Mast-Up" button.
9. Press each "Light" button several times to turn the lights on and off.
10. Tilt and pan the lights, and check the lights again.
11. If the optional strobe/beacon light is installed, press the "AUX" button several times to turn the
light on and off.
12. To ensure that the mast is properly sealed, while the mast is fully extended, watch for any
type of mast lowering.
13. Press and hold the "Mast-Down" button until the mast has completely stowed and then
release the button once the LED indicators turn off on the HHRC. The mast will power off
automatically upon reaching the stowed position.
14. Restart the system and rapidly press the "Mast-Up" button two times to invoke the Auto-Up
feature. Once the mast has fully deployed to the vertical position, press the "Mast-Down"
button two time rapidly to invoke the Auto Stow® feature. The mast will stow and power itself
off.
Note: Before delivery of a new system, the 90° and Mast Stowed (Near 0°) switches are set and
tested for a flat surface. If the mounting surface is not flat, the 90° and Mast Stowed switches
may need adjusted to function properly. If necessary, refer to Section 7.5 for details on adjusting
the 90° and Mast Stowed (Near 0°) switches.