Will Burt Night Scan Powerlite Operating Instructions Manual page 88

Table of Contents

Advertisement

NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
Table 9-2 Error and Warning Codes for RCP (Continued)
Message
WRN 2,06
Pan Stuck
2,01
Pan Limit Overlap
2,03
TILT pot stuck
Positioner
Only
2,04
PAN pot stuck
Positioner
Only
2,07
Communication Timeout
2,08
Microprocessor error
2,09 RCP
(Left) Tilt Up wrap
Only
around
2,10 RCP
(Left) Tilt Down wrap
Only
around
2,09
Pan Pot Failure
Positioner
Only
2,10
Tilt Pot Failure
Positioner
Only
PAGE 86 OF 98
Meaning
Checked only when
moving out of a limit
position.
The software indicates
the state of the pan
photo sensor has not
changed even though
the motor has been told
to move for more than 1/
2 second
The software indicates
both pan photo sensors
are blocked
simultaneously
No movement detected
in expected direction for
2.0 seconds
The RCP or P-T Drive
board has not sent out
communications
recently
The RCP board has sent
an invalid message
The software indicates
the same photo sensor
was made before the
opposite limit photo
sensor was made to
stop rotation. This
indicates wrap around
The Positioner software
indicates the pot
feedback voltage is out
of acceptable operating
range
Root Issue
Something is preventing
movement of pan
mechanism, the motor is
defective, or the RCP
board is defective
Foreign material in one
of the photos sensors or
faulty photo sensor
Soft stops are not set,
something is preventing
the sense voltage (pot)
movement, the motor is
defective, the sense
voltage is going the
wrong way (miswire), or
the P/T drive board is
defective
Bad board or connection
in communications link
Indicates a software
problem
1. The flag that
interrupts the light may
need to be adjusted to
go deeper into the photo
sensor
2. The limit photo sensor
is defective
Defective pot, incorrect
wiring, bad connection,
defective P-T board
Potential Cause
TP-4723701-U
MAY 2021

Advertisement

Table of Contents
loading

Table of Contents