For Condition #2 (12 VDC with >20 Amps per circuit) a solenoid valve is added to the system to
manage the higher current load. This solenoid valve assembly includes a separate terminal block
to land the 12 VDC light power. Connect the left and right light power to the terminal block as
shown in Figure 5-11 following the polarity listed on the terminal block label. Note this only
applies to 12 VDC high current applications. The solenoid valve is not installed for systems under
Condition #1.
Solenoid Valve
Terminal Block
Base Board
Ground Bar
Figure 5-11 Solenoid Valve Light Power Connection Point (for 12VDC High Current)