Attaching the Power Converter

Note: The Power Converter is standard with the Night Scan Powerlite HDT, but it is optional for
the Night Scan Powerlite and Night Scan Powerlite Xtreme models.
Mount the power converter vertically (fins up and down) for better heat dissipation (Figure 5-13).
The best practice is to mount the power converter in a fan-cooled enclosure. Do not mount the
power converter in the engine compartment or an enclosed space without ventilation.
Fins
5.8

Test the Installation

Review the Operation Section 6 and Safety Summary Section 1 and observe all safety dangers,
warnings, and cautions before proceeding to test the installation. If any part of the testing fails,
check the LEDs on the controller and Base Board.
To test the installation, proceed as follows:
1. Reconnect power to the mast and light circuits.
2. Turn the E-Stop button to reset and enable the system (if it was pressed).
3. Push and hold the green "NFPA Start" button until the system begins power-up.
4. Check for proper clearance above the mast.
5. Press and hold the "Mast-Up" button until the mast tilts to vertical and the mast starts to raise.
Once the mast starts to raise, release the "Mast-Up" button.