Spare Parts; Periodic Inspections - Will Burt Night Scan Powerlite Operating Instructions Manual

Table of Contents

Advertisement

NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
7.3

Spare Parts

To order spare or replacement parts, always refer to the mast model number and serial number.
The model number, serial number, and additional information is located on the mast Identification
Plate on the mast base. To order spare parts contact The Will-Burt Company.
7.4

Periodic Inspections

This section describes the systematic care and inspection of equipment to keep it in safe
operating condition and to prevent breakdowns. If the system does not perform as required, see
Section 9 for troubleshooting. If anything looks wrong and cannot be diagnosed and/or fixed,
contact The Will-Burt Company. Table 7-1 provides a schedule of periodic inspections and
procedures required to keep the Mast System in safe operating condition.
Frequency
As Needed; In
Inspect to ensure the Mast System is
salt water or
kept clean and free from foreign
sandy
material. Dirt, grease, oil, sand and
environments
debris may cover up a serious
clean the mast
problem.
every 3 months.
During Operation
Inspect for damage during operation.
Monthly
Visually observe tube motion during
extension and retraction to ensure
the tubes move smoothly and do not
cause excessive impact loads when
each tube fully extends or retracts.
Monthly
Inspect for any damage to electric
cables and pneumatic tubes.
Monthly
Test the Vehicle Interconnect safety
warning circuit to ensure the vehicle
driver is warned or prevented from
driving with the mast deployed.
Monthly
Inspect the Look-Up light lens for
debris or dirty lens that prevent light
from reaching the operating space.
Monthly
Inspect all hardware to ensure
fasteners are not damaged,
loosening, backing out or missing.
Take special note of hardware
keeping the payload mounted, mast
collar bolts, and hardware used to
mount the mast to the support
structure.
TP-4723701-U
MAY 2021
Table 7-1 Periodic Inspections
Inspection
OPERATING INSTRUCTIONS
Action
Clean the mast per the procedure
in section 7.2.
If damage is apparent, do not use
the mast, and have it serviced
prior to use.
Clean and lubricate the mast per
the procedure in section 7.2. If the
condition remains after lubrication,
cease all mast use and contact
Will-Burt Service immediately.
Replace cables/tubes as required.
Repair the interconnect circuit if
not functioning properly.
Make sure the lens is cool and
clean the lens with a mild cleaner
and soft cloth.
Tighten or replace any loose,
damaged or missing fasteners.