NIGHT SCAN POWERLITE, POWERLITE XTREME, AND POWERLITE HDT
OPERATING INSTRUCTIONS
Table 9-1 Error and Warning Codes for Base Board (Continued)
Message
1,12
Sensor Output Error
Roof-mount - Actuator at
90° magnetic sensor
Vertical - Upper
magnetic sensor switch
1,13
RCP STOWED
magnetic sensor -
Sensor Output Error
(Upper magnetic sensor
on Vertical)
1,14
Mast Down (lower
magnetic sensor)
1. Sensor Output Error
2. Sensor State Error
1,15
At 90° (Actuator) -
Sensor State Error
1,16
Not Used
1,17
Well Closed (Vertical
with well cover) - Switch
Output Error
1,18
Well Closed (Vertical
with well cover) - Sensor
State Error
PAGE 84 OF 98
Meaning
Sensor outputs are bad
Sensor outputs are bad
1. Sensor outputs bad.
They have not been
opposite for >250ms.
or
2. Mast was told to go
up, and the sensor
indicates it did not move
after 8 seconds (v7.2),
or 15 seconds (v7.3).
3. Sensor is not seeing
magnet when mast is
fully retracted
Checked at power up
after stowing. Sensor
outputs are O.K., but
sensor shows wrong
polarity for nested state
Not Used
Sensor outputs are bad
Switch outputs are O.K.,
but show wrong polarity
for Well Closed
Root Issue
Wiring error, faulty
sensor
(Vertical only) mag
switch positioning. Note:
Sensor is only active as
mast tube magnet goes
by. Software watches for
direction of travel and
sensor activation to
determine if mast is "up"
or "down"
Wiring problem,
defective magnetic
sensor
1. There may be a wiring
problem, or a defective
magnetic sensor.
or
2. Defective magnetic
sensor, air supply
inadequate, or external
magnet affecting sensor.
3. Sensor not seeing
magnet - sensor needs
to be re-aligned
Board was changed or
updated while the mast
was at 90°
Not Used
D7 Green = Closed
D8 Yellow = Not Closed
Switch wiring, defective
switch, board
Potential Cause
TP-4723701-U