6.1.3 Technical Data IZ16E

Position Indicator IZ16E
LCD-Display
Measuring unit
Perspective
Keyboard
Measuring principle
Measurement
Power supply
Power consumption
(with measuring system)
Battery life
Operating temperature
Storage temperature
Humidity
Velocity
Housing
Housing dimensions
Installation depth
Front panel cut out
Protection class front
Protection class back
7 decades (digit height 14mm)
With sign, battery status and measurement units
mm, m, Inch or °
12 o'clock
Foil with softkeys
Magnetic, theoretically absolute
linear or rotative
1.5 V or 3.0 V (+24V on request)
< 1 mA with 1.5V
1...3 years (depending on the battery-type)
0 °C ... + 50 °C
-10 °C ... +60 °C
max. 80 %, non-condensing
max. 4 m/s
Norm panel housing, ABS plastic, black
W x H = 96 x 72 mm
30 mm -> depending on the version, see section 6.1.2
60 mm -> option AG, see section 6.1.2.6
W x H = 93 x 67 mm
IP 54 (when installed with sealing)
IP 43 (when installed without sealing)
IP 50 (option AG)
IP 64 (option AG1)
IP 40
IP 50 (option AG)
IP 64 (option AG1)