List Of Details - Mitsubishi Electric MELSERVO-J3 Series Instruction Manual

Sscnet interface direct drive servo
Hide thumbs Also See for MELSERVO-J3 Series:
Table of Contents

Advertisement

5. PARAMETERS

5.2.2 List of details

Classification
No.
Symbol
PA01
PA03
*ABS
PA14
*POL
Name and function
For manufacturer setting
Do not change this value by any means.
Absolute position detection system
Set this parameter when using the absolute position detection system in
the position control mode.
0 0 0
Selection of absolute position detection system
(Refer to MR-J3- B Servo Amplifier Instruction
Manual chapter 12)
0: Used in incremental system
1: Used in absolute position detection system
If the absolute position detection system is
enabled when the incremental system is being
used, parameter error (37) occurs.
POINT
This parameter cannot be used in the speed control
mode.
Rotation direction selection
Select direct drive motor rotation direction relative.
Direct drive motor rotation direction
Setting
When positioning address
increases
0
CCW
1
CW
POINT
This parameter cannot be used in the speed control
mode.
When positioning address
decreases
CW
CCW
Forward rotation (CCW)
Reverse rotaion (CW)
5 - 3
Initial
Unit
Setting range
value
0060h
0000h
Refer to the
name and
function
column
0
0 1