5.1. Device Layout

1.
2.
3.
4.
1.
IR LEDs — Infrared LEDs illuminate nighttime scenes.
2.
Fine Focus Adjustment Ring — Turn the ring up to one revolution to make fine focus adjustments for the clearest image.
3.
Built-in Microphone — Picks up audio near the camera and streams it with video.
4.
PIR Sensor Motion Detector — Passive Infrared Sensor detects motions for triggering record and contact closure events.
5.
Built-in Speaker — Output audio from a connected device's microphone (if equipped) like a PC or smartphone.
6.
Relay Contacts (Spring Loaded Terminals) — Monitor the state of a contact closure (DI) or control a device via relay (DO)
during motion and alarm events.
7.
1/4"-20 Threaded Mounting Hole — Attach the included mounting base, or any base with male 1/4"-20 threads.
8.
Default Button — Press and hold for 30 seconds while powering the camera to return all camera settings to default.
9.
Audio Out (1/8" / 3.5mm Stereo) — Connect a 1/8" (3.5mm) stereo-mini cable to an amplifier input to send audio out from the
camera's web interface.
10. Ethernet Connection (RJ45) — Connect to network switch for communication to and from the camera. Pin out follows EIA
standard 568-B. If the network port used supports PoE standard IEEE 802.3af then power can be provided on the Cat5e/6
connection.
11. 12V DC Power In — No power supply is needed if PoE is being used to power the camera via the Ethernet connection.
Connect to a 12V DC power supply if PoE is not being used. A power supply is not included with the camera.
Warning! Use only a 12V DC power supply with this camera. Higher voltages or AC current will cause permanent damage
that is not covered by the warranty.
12. Service Tag — Displays the service tag number and camera model information.
13. MAC Address Tag — The MAC address is used during setup and is helpful information to save. Record the MAC addresses of
all equipment in the system in your job records.