7
I/O SIGNAL
7.1

I/O SIGNAL LIST

7.1.1

Remote I/O (64 points fixed)

Device
No.

RYn0
Forward rotation command
RYn1
Reverse rotation command
High-speed operation command
RYn2
(terminal RH function)
Middle-speed operation command
RYn3
(terminal RM function)
Low-speed operation command
RYn4
(terminal RL function)
Jog operation selection
RYn5
(terminal Jog function)
Second function selection
RYn6
(terminal RT function)
Current input selection
RYn7
(terminal AU function)
Selection of automatic restart after
RYn8
instantaneous power failure
(terminal CS function)
Refer
Signal
to
page
70

70

70

70

70

70

70

70

70
,


Device
No.

RXn0
Forward running
RXn1
Reverse running
RXn2
Running (terminal RUN function)
Up to frequency
RXn3
(terminal SU function)
Overload alarm
RXn4
(terminal OL function)
Instantaneous power failure
RXn5
(terminal IPF function)
Frequency detection
RXn6
(terminal FU function)
RXn7
Error (terminal ABC1 function)
RXn8
— (terminal ABC2 function)
Details of remote input and output signals
Refer
Signal
to
page
72
72
72

72

72

72

72

72

72

7
61