Remote Register (128 Words Fixed) - Mitsubishi Electric CC-Link IE TSN FR-A8NCG Instruction Manual

Table of Contents

Advertisement

7.1.2

Remote register (128 words fixed)

Address

Upper 8 bits
RWwn
Set frequency (0.01 Hz increments)
RWwn+1
Reserved
RWwn+2
Torque command / torque limit
RWwn+3
Reserved
RWwn+4
PID set point (0.01% increments)
RWwn+5
PID measured value (0.01% increments)
RWwn+6
PID deviation (0.01% increments)
RWwn+7 to
Reserved
RWwn+F
Link parameter
RWwn+10
extended setting
RWwn+11
Write data
Link parameter
RWwn+12
extended setting
RWwn+13
Write data
Link parameter
RWwn+14
extended setting
RWwn+15
Write data
Link parameter
RWwn+16
extended setting
RWwn+17
Write data
64
Details of remote input and output signals
Description
Lower 8 bits
,





Instruction code

Instruction code

Instruction code

Instruction code

Refer
to
Address

Upper 8 bits
page
74
RWrn
Reply code
RWrn+1
Reserved
74
RWrn+2
Reply code
RWrn+3
Reserved
74
RWrn+4
Reply code
74
RWrn+5
Reply code
74
RWrn+6
Reply code
RWrn+7 to
Reserved
RWrn+F
74
RWrn+10
Reply code
75
RWrn+11
Read data
74
RWrn+12
Reply code
75
RWrn+13
Read data
74
RWrn+14
Reply code
75
RWrn+15
Read data
74
RWrn+16
Reply code
75
RWrn+17
Read data
Description
Lower 8 bits





Refer
to
page
76
76
76
76
76
77
77
77
77
77
77
77
77

Advertisement

Table of Contents
loading

This manual is also suitable for:

800 series

Table of Contents