Mitsubishi Electric CC-Link IE TSN FR-A8NCG Instruction Manual page 76

Table of Contents

Advertisement

Device No.
Signal
RWw11,
RWw13,
RWw15,
Write data
RWw17,
RWw19,
RWw1B
RWw21
Fault history No.
RWw26
Monitor code 1

RWw27
Monitor code 2

RWw28
Monitor code 3

RWw29
Monitor code 4

RWw2A
Monitor code 5

RWw2B
Monitor code 6

RWw2C
Monitor code 7

RWw2D
Monitor code 8

RWw2E
Monitor code 9

RWw2F
Monitor code 10

Setting increment differs according to the combination of Pr.37, Pr.144, and Pr.811. (Pr.811 is only available for the FR-A800 series.)
Refer to the Instruction Manual (Detailed) of the inverter for the details.

When Pr.541 Frequency command sign selection = "1", the setting value has either + or -. When the setting value is negative, the
command is the inverse from the command.
Setting range: -327.68 Hz to 327.67 Hz (-327.68 to 327.67) 0.01 Hz increments.
For details refer to

When Pr.128 = "50, 51, 60, 61", they are valid. If the data outside the range is set, the previous setting is retained.
Refer to the Instruction Manual (Detailed) of the inverter for details of Pr.128.

Write data is in hexadecimal, and only two digits are valid. (The upper two digits are ignored.)

The signal is valid only for the FR-A800 series.

The value in RWw2 is used as the torque limit value during speed control or position control, and as the torque command value during
torque control. (Torque control cannot be performed with a PM motor.) To use the value as the torque limit value, set Pr.810 = "2".

This setting is available only when the inverter supports this function. (Refer to
Set the data specified by the instruction code of RWw10, 12, 14, 16, 18 and 1A (when required).
RWw10, 12, 14, 16, 18, and 1A correspond to RWw11 13, 15, 17, 19, and 1B, respectively.
Set "1" in RY25 after setting the instruction codes (RWw10, 12, 14, 16, 18, and 1A) and the
corresponding register.
Set "0" when the write code is not required.
Set the individual fault number of the fault history that you want to read.
Up to the 8th previous fault can be read.

Last two digits: H00 (Latest fault) to H07 (8th latest fault)
Set H08 to HFF to make the fault history No. to "0."
Set the monitor code to be monitored (refer to
specified monitored data is stored in RWr26 to RWr2F.
If a monitor code out of the setting range is set, no item is monitored (the monitor value is fixed to 0).

page
53.
Description
page
83). By setting "1" in RY20 after setting, the
page
84.)
Details of remote input and output signals
7
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

800 series

Table of Contents