Mitsubishi Electric CC-Link IE TSN FR-A8NCG Instruction Manual page 63

Table of Contents

Advertisement

Device
No.

Output stop
RYn9
(terminal MRS function)
Start self-holding selection
RYnA
(terminal STOP function)
RYnB
Reset (terminal RES function)
RYnC to
RYnF
Reserved
RY(n+1)0 to
RY(n+1)2
RY(n+1)3 to
Reserved
RY(n+1)F
RY(n+2)0
Monitor command
RY(n+2)1
Frequency setting command (RAM)
Frequency setting command
RY(n+2)2
(RAM, EEPROM)
RY(n+2)3
Torque command / torque limit (RAM)
Torque command / torque limit
RY(n+2)4
(RAM, EEPROM)
RY(n+2)5
Instruction code execution request
RY(n+2)6 to
Reserved
RY(n+3)9
RY(n+3)A
Error reset request flag
62
Details of remote input and output signals
Refer
Signal
to
page
70

70

70

71
71
71
71

71

71
71
Device
No.

RXn9 to
Reserved
RXnF
RX(n+1)0
Pr.313 assignment function (DO0)
RX(n+1)1
Pr.314 assignment function (DO1)
RX(n+1)2
Pr.315 assignment function (DO2)
RX(n+1)3 to
Reserved
RX(n+1)F
RX(n+2)0
Monitoring
RX(n+2)1
Frequency setting completion (RAM)
Frequency setting completion
RX(n+2)2
(RAM, EEPROM)
Torque command / torque limit setting
RX(n+2)3
completion (RAM)
Torque command / torque limit setting
RX(n+2)4
completion (RAM, EEPROM)
RX(n+2)5
Instruction code execution completion
RX(n+2)6 to
Reserved
RX(n+3)9
RX(n+3)A
Error status flag
Refer
Signal
to
page
72

72

72

73
73
73
73

73

73
73

Advertisement