5.6.2

Subnet mask setting (Pr.438 to Pr.441)

When the inverter station number is specified using the station number switches on the circuit board of the FR-A8NCG, the
setting in the master is used for the subnet mask setting. (The settings from Pr.438 to Pr.441 are invalid.) When the station
number switches are set to "0 (H00) or 255 (HFF)", enter the subnet mask of the network to which the inverter belongs in
Pr.438 to Pr.441.
* * * . * * * . * * * . * * *
5.6.3

Selecting the communication speed (Pr.1130)

Set the communication speed using Pr.1130 Link speed selection.
Pr.1130 setting
Communication speed
0 (initial value)
1 Gbps
1
100 Mbps
Set the value in the first octet in Pr.438.
Set the value in the second octet in Pr.439.
Set the value in the third octet in Pr.440.
Set the value in the fourth octet in Pr.441.