Mitsubishi Electric CC-Link IE TSN FR-A8NCG Instruction Manual page 38

Table of Contents

Advertisement

Pr.340
Pr.79
Operation mode at power ON or power
setting
setting
0 (initial
External operation mode
value)
1
PU operation mode
2
External operation mode
0
(initial
3, 4
External/PU combined operation mode
value)
6
External operation mode
X12 (MRS) signal ON: external operation mode
7
X12 (MRS) signal OFF: external operation mode
0
NET operation mode
1
PU operation mode
2
NET operation mode
1, 2
3, 4
External/PU combined operation mode

6
NET operation mode
X12 (MRS) signal ON........ NET operation mode
7
X12 (MRS) signal OFF........external operation mode
restoration
Operation mode switchover
Switching among the External, PU, and NET operation
mode is enabled.
,


PU operation mode fixed
Switching between the External and Net operation mode is
enabled.

Switching to the PU operation mode is disallowed.
Operation mode switching is disallowed.
Switching among the External, PU, and NET operation
mode is enabled while running.

Switching among the External, PU, and NET operation
mode is enabled.
,


External operation mode fixed (Forcibly switched to
External operation mode.)
Same as when Pr.340 = "0"
INVERTER SETTING
5
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

800 series