Figure 8-1. Overlay Panel Installation - Perlick CR30R Series Service Manual

Column refrigeration
Table of Contents

Advertisement

8.0 Doors, Drawers, Shelving and Misc.
8.1
Overlay Panel Installation
and Adjustments
Typical panel dimensions are based on 84"
(2134mm) finished height with 1/8" (3mm)
reveals. Template must be adjusted for panels
exceeding typical dimensions.
1. Place panel face down on a protected work
surface.
2. Attach six clips to the back of overlay in
locations indicated in wood overlay drawing
below.
3. Use provided #10 x 1/2" screws to attach clips
to overlay.
4. Overlay then slides onto door face.
74
5. Attach overlay to door adjustment brackets using
6. Once mounted, adjust overlay to match adjacent
7. Close the door to make adjustments to align
8. For up and down adjustments, turn the height
9. Adjust the screws as needed to achieve an even
10. Once final adjustments are made to the position

Figure 8-1. Overlay Panel Installation

Column Refrigeration Service Manual
remaining #10 x 1/2" screws.
cabinetry.
panels and reveals.
adjustment screws in the top bracket ( see Top
of Door illustration, Figure 8-2, on page 75 ) in
and out.
reveal on each side of the door overlay.
of the door overlay, secure the overlay in place by
installing the bottom overlay brackets.
See Figure 8-1.
BOTTOM OF DOOR