Door Panel Installation/Adjustment - Perlick CR24 Installation Instructions Manual

24 inch column refrigeration
Table of Contents

Advertisement

DOOR PANEL INSTALLATION
Typical panel dimensions are based on 84" (2134) finished
height with 1/8" (3) reveals. Template must be adjusted for
panels exceeding typical dimensions.
Place panel face down on a protected work surface. Attach
six clips to the back of overlay in locations indicated in wood
overlay drawing below.
Use provided #10 x 1/2" screws to attach clips to overlay.
Overlay then slides onto door face. Attach overlay to door
adjustment brackets using remaining #10 x 1/2" screws. Once
mounted, adjust overlay to match adjacent cabinetry.
16 | perlick.com/residential
PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
INSTALLING DOOR OVERLAY PANELS
DOOR OVERLAY PANEL ADJUSTMENT
Close the door to make adjustments to align panels and reveals.
For up and down adjustments, turn the height adjustment
screws in the top bracket (see Top of Door illustration on page
17) in and out. Adjust the screws as needed to achieve an even
reveal on each side of the door overlay.
Once final adjustments are made to the position of the door
overlay, secure the overlay in place by installing the bottom
overlay brackets as shown in Bottom of Door illustration below.
BOTTOM OF DOOR

Advertisement

Table of Contents
loading

Table of Contents