Figure 6-5.1. Evaporator Air Outlet Louvers; Figure 6-5.2. Evaporator Air Damper Outlet Openings; Figure 6-6. Condenser Airflow Divider - Perlick CR30R Series Service Manual

Column refrigeration
Table of Contents

Advertisement

Column Refrigeration Service Manual

Figure 6-5.1. Evaporator Air Outlet Louvers

Ensure the condenser airflow divider is
installed on the lower interior portion
of the door. This divider prevents direct
circulation of machine compartment
air. If missing, unit will run extremely
inefficiently and extreme high discharge
pressures and temperature which could
lead to compressor damage. See Figure
6-6.
Figure 6-6. Condenser Airflow Divider
Return to
Table of Contents

Figure 6-5.2. Evaporator Air Damper Outlet Openings