CL33600 Series Cylindrical Lock
5.
Installing Lock - Feed lock body and wire through 2-1/8" diameter hole from outside of door (Fig. 5a).
Be sure latch engages lock body as shown (Fig. 5b):
Important: Door must remain open during installation.
Use door stop
Outside Face of Door
6.
Install Inside Spring Cassette:
a. Feed lock body wires and cassette (REX) wires in slot on face of door (Fig. 6a)
Note: Be careful to keep wires in slot cut into door.
b. Tightening using two #12-24 screws.
Note: DO NOT PINCH wires when tightening.
Lock Body Wires
Fig. 6a
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
Fig. 5a
Inside Face of Door
Keep wires in slot:
DO NOT pinch under
Spring Cassette
REX Wires
Ground Wire
10
Fig. 5b
Spring Cassette