Download Print this page

Assa Abloy Corbin Russwin Access 600 CL33600 TCRNE1 Series Installation Instructions Manual page 7

Cylindrical lockset m812 - iclass se reader option
Hide thumbs Also See for Corbin Russwin Access 600 CL33600 TCRNE1 Series:

Advertisement

CL33600 Series Cylindrical Lock
Typlcal CL33600 x M812 Series Lock Application Diagram (12/24VDC Lock)
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
Reader Electronics Require 12 or 24VDC UL294 Listed, Power Limited Power Supply (or UL603)
12/24VDC SYSTEM
Reader Draw = 150mA
12VDC Solenoid Draw = 500mA
12VDC Total Current Draw = 650mA
24VDC Solenoid Draw = 250mA
24VDC Total Current Draw = 400mA
3287 Door
Position Switch
12 Conductor
ElectroLynx Harness
From McKinney
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
6) Wiring Diagrams (Continued)
MODE 1: LED WIRE NOT USED = RED LED 'ON' WHEN POWERED
QC12 Electric
Hinge From
McKinney
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
Lockbody
H
Power Supply
120 VAC
(By Others)
12/24VDC
Input
-
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO) - Orange, 5
RX (COM) - Blue, 6
*EARTH GROUND - Brown, 7
LED - Yellow, 8
Not Used
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
7
N
G
Access 600 Reader Electronics
Require 12 or 24VDC UL294 Listed,
Power Limited Power Supply (or UL603)
+
ULC-S319 compliance:
EAC power supply utilizing battery backup
(30 minutes operation) is required.
Access 600 Series M812
UL294 Listed EAC Panel
(-)
12/24VDC
(+)
DATA 1
DATA 0
RX (NO)
(By Others)
RX (COM)
Use (NC) for
Fail Safe
Operation
Lock Relay
DPS
(NO) Fail
DPS
Secure
Operation
Electrical
Access
Control
Panel

Advertisement