Page 1
Certification Exhibit FCC ID: U4A-SCYICLS0 IC: 6982A-SCYICLS0 FCC Rule Part: 15.225 IC Radio Standards Specification: RSS-210 ACS Report Number: 11-0125.W06.11.A Manufacturer: Assa Abloy, Inc. Models: TCWI1-M812/M813, TCIP1-M812/M813 Manual 5015 B.U. Bowman Drive Buford, GA 30518 USA Voice: 770-831-8048 Fax: 770-831-8598...
Page 2
ccess 800 Installation Instructions For ML20800 TCWI1/TCIP1 Series FM 335 Mortise Lockset (Rev. 0 /2011) Please read these instructions carefully to prevent missing important steps. Please Note: Improper installation may result in damage to the lock and void the factory warranty. Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Page 3
ML20800 TCWI1/ TCIP1 Series Mortise Lock Table of Contents 1) Warning………………………………………………………………. 2) General Description…………………………………………………. 3) Specifications/ Features…………………………….……………… 4) Product Illustration……………..……………………………………. 3 5) Installation Instructions……………………………………………… 4-10 6) Wiring Diagrams…………………………………………………….. 11-17 7) Mechanical Operation Check ……………………………………… 18 8) Electrical Operation Check…………………………………………. 19 1) Warning Warning: Changes or modifications to this unit not expressly approved by ASSA ABLOY Inc.
ML20800 TCWI1/TCIP1 Series Mortise Lock 2) General Description The Corbin Russwin Access 800 Series mortise locks are available in WiFi (WI1) and PoE (IP1) configurations. When coupled with third party software the WI1 and IP1 offer a complete integrated access control system. The Access 800 may be used for both indoor and outdoor applications (weather gaskets supplied).
4) Installation Instructions Verify Hand and Bevel of door. Illustrations shown are as viewed from the outside or secure side of opening. Left Hand Left Hand Right Hand Right Hand Hinges Left. Reverse Bevel Hinges Right. Reverse Bevel Open Inward. Hinges Left.
Page 7
Installation Instructions Lock Assembly Instructions Align bevel accordingly. Engage 7/64 Allen wrench on to cap screw required for step 2 page 6. Feed connector and wires through 1 (25) dia. wire access hole. Insert lockbody into mortised cutout in door and hold loosely in place with (2) #12x1" lockbody screws. 7/64 Allen Wrench Inside of Door...
Page 8
Installation Instructions Installation of Outside Escutcheon 1. For exterior applications, an optional M99 Weatherseal Gasketing Kit can be ordered when a device is ordered. this kit includes gaskets and a conduit. When ordering the kit separately, order part number 794F929. The gaskets may be used as a seal between the escutcheon and the door surfaces.
Page 9
Installation Instructions Installation of Inside Escutcheon NOTE: Connectors go on only one way. Do not offset connector and be sure they are completely seated. 1. Remove black battery cover from the eschutcheon with High Security T20 Trox bit provided. 2. Connect Ground wire to Ground terminal, Keypad ribbon cable connector to controller, lockbody harness to motor connector, DPS conector on lockbody harness to remote power and DPS harness, and connect remote power if applicable.
Page 10
Installation Instructions Installation of Inside Escutcheon (continued) CAUTION: Do not allow lockbody harness wires to enter cylinder hole in lockbody. Wire damage and/or malfunction of the lock may occur. 1. Turn inside lever to the horizontal position and rotate the turnpiece to the vertical position. Slide onto spindle halfway.
Page 11
Installation Instructions Installation of Armored Front Plate 1.Install armored front plate using two #8-32 x 1/4"screws provided. Lockbody screws Armored Front Plate Front Plate screws...
Installation Instructions Battery Installation 1. Remove battery keeper by lifting top tab and pulling away from the unit. 2. Install (6) AA Batteries into controller compartment being careful to align +/- polarity properly. 3. Install Battery Keeper by first inserting bottom tabs in bottom slots of controller. Lift the top tab over batteries and snap into position.
Page 13
TEST FOR PROPER OPERATION BEFORE CLOSING DOOR Corbin Russwin, Inc. Technical Product Support: Canada: Assa Abloy DSS Canada 160 Four Valley Drive 225 Episcopal Road Corbin Russwin, Inc. Berlin, CT 06037-4004 Phone 800-810-WIRE (9473) Vaughun, ONT L4K 4TG www.yalecorbin.on.ca www.corbinrusswin.com...
Page 14
Installation Notes 1. With new applications, an ElectroLynx™ door harness with 8 and 4 pin connectors will be pre-installed inside door by ASSA ABLOY door manufacturer when specified during ordering process. 2. Wiring to pigtail harness is per facility wiring requirement. ElectroLynx™ connector terminations and wire colors all match.
Page 15
6) ML20800 Hard Wiring Instructions 6.4) Hard Powered Connections ELECTRO END OF INSTALLATION INSTRUCTIONS...