8.
Installing Outside (Reader) Escutcheon and Ground Wire:
a. Insert reader assembly and route wires through door (Fig. 8a).
b. Install two #8-32 x 1-3/4" flat head screws (Fig. 8b).
Fig. 8a
9.
Secure Mounting Plate using two #8 x 3/4" combination
surface mount screws.
Add Gasket (if necessary):
Remember an inside gasket must be used
when installing in an outdoor application.
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
7) Installation Instructions (Continued)
12
Ground Wire
Ring Terminal
Fig. 9a
Fig. 8b
Inside Face of Door
Gasket required
for exterior door
applications.
Fig. 9