Please read these instructions carefully to prevent missing important steps.
Please Note: Improper installations may result in damage to the lock and void the factory warranty.
Important: The accuracy of the door preparation is critical for proper functioning and security of this lock.
Misalignment can cause premature wear and a lessening of security.
For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473)
Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company.
All rights reserved. Reproduction in whole or in part without the
express written permission of Corbin Russwin, Inc. is prohibited.
Mortise Lockset Installation Instructions
ML20600 TCRNE1 Series
M812 - iCLASS SE
Attention Installer
Reader Option
®
FM312 10/18
WARNING
This product can expose
you to lead which is
known to the state of
California to cause cancer
and birth defects or other
reproductive harm. For
more information go to
www.P65warnings.ca.gov.
08/2018

Advertisement

loading
Need help?

Need help?

Do you have a question about the Corbin Russwin Access 600 ML20600 TCRNE1 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Assa Abloy Corbin Russwin Access 600 ML20600 TCRNE1 Series

  • Page 1 08/2018 For Technical Assistance call Corbin Russwin at 1-800-810-WIRE (9473) Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 2: Table Of Contents

    Observe precautions for handling electrostatic sensitive devices. Warning: To comply with “Fire Listed” doors, only alkaline batteries must be used. Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the...
  • Page 3: General Description

    Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), CSA 22.1, Canadian Electrical Code (CEC), Part I, Safety Standard for Electrical Installations, local codes, and the authorities having jurisdiction. Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the...
  • Page 4: Product Illustrations

    ML20608/ML20609 Fail Safe (SAF 816F038 [handing]* ML20608/ML20609 Fail Safe (SAF) Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 5: Wiring Diagrams

    — — 1,500 — — — — — — Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 6 FM406 for the wiring of RX & DPS outputs. Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 7: Installation Instructions

    (ElectroLynx) from McKinney Outside Face of Door Inside Face of Door Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 8 Anti-friction Latch Tail Fig. 3c Lock Front Fig. 3d Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 9 *RX output only configurable for locks with end-of-line resistance monitoring. Default is normally open. Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 10 ElectroLynx® Wires Lock Body Wires Fig. 6b Fig. 6a Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 11 Remove backing and place gasket on door (Fig. 8). Fig. 8 Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 12 (Solenoid, pos) DPS (COM) PWR POS DATA 0 RX (COM) Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 13 Flat Head Undercut Combo Screw Fig. 11c Fig. 11b Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 14 8-32 X 1/4” Phillips Flat Head Undercut Machine Screw Fig. 13 Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 15 Step 3 Outside Face of Door Inside Face of Door Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 16 Make sure O/S lever is fully inserted into adapter plate before aligning adjustment bolt. Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 17 Step 2 Inside Face of Door Outside Face of Door Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 18 Armored Front (2) #8-32 x 1/4” Fig. 14 Tighten Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 19: Operational Check

    Displays measured end- of-line resistor values (if applicable) Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited.
  • Page 20 Phone: 800-543-3658 Fax: 800-447-6714 corbinrusswin.com Copyright © 2017 Corbin Russwin, Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without the express written permission of Corbin Russwin, Inc. is prohibited. Patent pending and/or patent - www.assaabloydss.com/patents.