Fieldbus Board - Okura Yusoki A Series Original Instructions Manual

Hide thumbs Also See for A Series:
Table of Contents

Advertisement

3.7. Fieldbus board (Ethernet/IP AB6214)
The arrangement of LED's displays on fieldbus board is as follows.
# Item
1 Network Status LED
2 Module Status LED
3 Link/Activity
4 Ethernet Interface
Network Status LED
Note: A test sequence is performed on this LED during startup.
LED State
Off
Green
Green, flashing
Red
Red, flashing
Module Status LED
Note: A test sequence is performed on this LED during startup.
LED State
Off
Green
Green, flashing
Red
Red, flashing
LINK/Activity LED
LED State
Off
Green
Green, flickering
Ethernet Interface
The Ethernet interface supports 10/100Mbit, full or half duplex operation.
Description
No power or no IP address
On-line, one or more connections established (CIP Class 1
or 3)
On-line, no connections established
Duplicate IP address, FATAL error
One or more connections timed out (CIP Class 1 or 3)
Description
No power
Controlled by a Scanner in Run state
Not configured, or Scanner in Idle state
Major fault (EXCEPTION-state, FATAL error etc.)
Recoverable fault(s)
Description
No link, no activity
Link established
Activity