Chapter 4 Basic Testing
VT-100 emulation
78
– Move Keyboard. Use this softkey to move the
keyboard to the top or bottom of the terminal screen.
This is helpful if the keyboard is blocking the display of
key data.
– Autobaud. Use this softkey to send a series of
sequential space characters to force the network
element to re-evaluate its baud rate.
– Capture Screen. Use this softkey to capture the data
on the terminal screen and save it in an ASCII file.
– Exit. Use this softkey to end the session and return to
the Main screen.
3 To specify the settings required for the session, select
VT-100 Setup. The VT-100 Setup screen appears.
a Under Port Settings, specify values for the following:
Setting
Baud Rate
Data Bits
Parity
Stop Bits
Flow Control
T-BERD/MTS 5800 Getting Started Manual
Value
Select one of the predefined baud rates
ranging from 50 to 115200 Kbps.
Select the number of data bits (ranging
from 5 to 8) that contain information.
These are the bits that are not used to
start, stop, or provide checksum values.
Indicate whether no parity check will be
performed (None), or whether the instru-
ment will use odd or even bits for parity
checking.
Indicate whether bit 1 or bit 2 will be
used as the stop bit.
Indicate whether the instrument will use
software (X ON / X OFF codes), hard-
ware, or no flow control (None).