13.4

External check of the storage cabinet

Is the ventilation strip on the cover of the storage cabinet clogged/soiled?
à After removing the cover (see chapter 13.10.10 on page 99), the ventilation strip can be cleaned
internally.
Is the room temperature secured at between +5 °C and +30 °C year-round (+18 °C is ideal)?
à Clarify with the customer how the temperature can be adhered to in the setup room. An active
ventilator may need to be installed.
Is the storage cabinet stable?
à If necessary, adjust with the screw feet.
Is the wall fastening stable?
à If necessary, tighten the screw or replace it.
13.5

Checking the system parameters (service)

The system parameters are checked via the web interface.
expansion stage of the energy store
Note: According to the
from the following image.
13.5.1

Checking the online status

On the homepage of the web interface, the
connection to the VARTA server (green = online, red = offline).
87
and after a
WWW symbol
(1) displays whether the energy storage system has a
software update
, the website can deviate