13.10.8

Dismounting and installing the battery modules

Improper handling of battery module.
Personal and material damage.
Switch off the battery module at the activation key (no. 3). (Keep button pressed down until the LED
goes out).
Unplug the following line connections:
Battery current connection (no. 5),
o
Comm 1 (no. 1) Warning and Fault
o
Comm 3 (no. 4) (RJ48)
o
Remove the fastening screws,
Pull the battery module on the tracks forward.
Installing the battery modules
Reinstall the battery modules in exactly the reverse order. Ensure that the assignment corresponds to the
previous condition.
Switch the battery module(s) on again. The LED
display on the battery modules displays the
functionality.
98
WARNING
Do not damage the battery module when dismounting and installing it.
Do not attempt a repair.
Battery modules are maintenance-free and must not be opened under any
circumstances.
Ensure that the battery modules
are switched off and that no LED display is lit up.
No.
Description
1
DRY contact
2
LED display
3
Activation button
No.
Description
4
CAN
Connections for battery
5
current