3.9.1

Battery module

VKB number
Electrochemistry cell
Nominal module capacity
Discharge depth
Useful module capacity
Connection
Cell monitoring
Dimensions in mm (W x H x D)
Weight
Packaging in mm (W x H x D)
3.9.2

Environmental rating

Environmental category
Classification of the wet rooms
Soiling grade
Ingress protection
Typical/max. Noise emission
Ambient temperature
Relative humidity
Max. altitude
Overvoltage category
Protection class
* The energy storage system is fully enclosed by a building and/or housing. Thus the energy storage
system is protected from sun, dust and other external influences. Additionally, the building and/or housing
is air-conditioned with regard to temperature, humidity and air filtering.
3.10

Derating

Derating means a temporary curtailment of the maximum performance of the battery converter in order to
prevent components from being heated excessively. VARTA energy storage systems are designed in such a way
that when the operating and environmental conditions are complied with the permitted operating temperature
is not exceeded and a derating is not necessary. To avoid a temperature derating of the energy store, you should
ensure that the energy store can issue the heat to the ambient air.
Frequent temperature-induced derating can have the following causes:
The system cannot issue enough heat to the ambient air because the air filters are soiled or have
failed.
The installation site of the energy store does not offer the requisite climatic conditions.
Atypical operation that deviates heavily from the photovoltaic cycle.
21
56462705099
Li-ions
6.5 kWh
90%
5.9 kWh
contact-safe
integrated
445 x 110 x 587
45 kg
800 x 460 x 600
Air-conditioned in inner rooms*
No wet rooms allowed
2
IP22
42 dBA / 49 dBA
+5 °C to +30 °C
< 80%
2000 m above sea level
III
1