Programming Menu
To select the panel operating logic, access the programming menu by pressing the buttons
SETUP, UP and DOWN at the same time on the main screen of the panel.
DESCRIPTION OF PARAMETER
Language
0 ITA / 1 ENG/ 2 FRA / 3 ESP
Operating Logic
COS-PHI Alarm Output
This parameter enables removal of the dry running alarm from the
cumulative alarm output.
Sensor Sensitivity (Sa - Sb - Sc - Sd)
This parameter enables display of sensor sensitivity. With the contacts open, if
a value of 99 is displayed, and a value of 45 is displayed with water present,
s e t s e n s i t i v i t y t o a n i n t e r m e d i a t e v a l u e , s u c h a s 7 5 .
User Menu
On completion of panel operation programming, enter the setup menu to configure the
various data for motor start-up. To access the user menu, press the button SETUP for 4
seconds in the main screen of the panel.
DESCRIPTION OF PARAMETER
Minimum Voltage
Set by default at -10% .
Modifications to operating limits beyond the default parameters will
i m m e d i a t e l y r e n d e r t h e w a r r a n t y n u l l a n d v o i d .
Maximum Voltage
Set by default at +10% .
Modifications to operating limits beyond the default parameters will
i m m e d i a t e l y r e n d e r t h e w a r r a n t y n u l l a n d v o i d .
6 6 6 21
VALUE
FAULT
0
0
8
-
Y
Y or N
0-99
75
VALUE
FAULT
207 (230)
-
360 (400)
253 (230)
-
440 (400)