Programming Menu
To select the panel operating logic, access the programming menu by pressing the buttons
SETUP , UP and DOWN at the same time on the main screen of the panel.
DESCRIPTION OF PARAMETER
Language
0 ITA / 1 ENG/ 2 FRA / 3 ESP
Operating Logic
Number of Pumps
ThThis parameter enables selection of the number of pumps in the system
(when 1 single pump is selected, the parameter PUMP ROTATION
ENABLED is disabled).
Pump rotation enabled
This parameter enables activation of pump exchange on each demand
from floats or pressure switches. Also, if the main pump thermal cutout
(current overload) trips, the second pump is enabled.
Minimum Level Alarm Output
This parameter enables removal of the minimum level alarm from the
cumulative alarm output.
COS-Phi Alarm Output
This parameter enables removal of the dry running alarm from the
cumulative alarm output.
User Menu
On completion of panel operation programming, enter the setup menu to configure the
various data for motor start-up.
11
VALUE
FAULT
0
0
3
-
As per order
1-4
Y or N
Y
Y or N
Y
Y or N
Y