DESCRIPTION OF PARAMETER
Minimum Voltage
Set by default at -10% .
Modifications to operating limits beyond the default parameters will
i m m e d i a t e l y r e n d e r t h e w a r r a n t y n u l l a n d v o i d .
Maximum Voltage
Set by default at +10% .
Modifications to operating limits beyond the default parameters will
i m m e d i a t e l y r e n d e r t h e w a r r a n t y n u l l a n d v o i d .
Maximum Current P1 / P2 / P3 / P4
This parameter enables entry of the maximum current for each motor.
Enter the maximum current value, increasing it by 10-15% with respect to the
rated motor value.
Modifications to operating limits beyond the parameters stated on the model
data plate will immediately render the warranty null and void.
Display brightness on standby
This parameter enables entry of the brightness setting applied when the
d i s p l a y s e t s t o s t a n d b y ( w a i t 9 s e c o n d s f o r a p r e v i e w ) .
Time For Entry To Set-up
This parameter enables entry of the time to keep the SETUP button
pressed for access to the set-up menu.
5.3 FUNCTION 3 - Drainage with "COS-Phi" power factor control
This operating mode is used for drainage applications with dry running safety control,
obtained from the power factor (where "Phi" is the timing angle between current and
voltage), without the need for external commands (float or pressure switch), enabling the
control of one or more pumps.
On selection of mode 3, all relative parameter fields for this function are enabled.
10
VALUE
FAULT
207 (230)
-
360 (400)
253 (230)
-
400 (400)
1 - ... A
As per order
0-9
4
2 - 30 Sec
3 Sec