Subscriber Connections

Refer to Figure 22 and Figure 23 on page 37 to install subscriber POTS, RF and/or Ethernet 
services.

POTS Connections

To connect POTS, complete the following steps:
1.Route the subscriber wires through the cable entry on the bottom of the enclosure. A tie 
2. If using an RJ‐11 connector directly, it is recommended that the cable be terminated with 
3. If using the Terminal Bridges, loosen each screw and attach the Green wire to the 
6418771XGX-5B
wrap point is provided for wire management (see Figure 22). 
the RJ‐11 plugs after the subscriber wires have been pulled through the cable entry. Each 
RJ‐11 connector is wired for a single line. There are two RJ‐11 jack holders molded into the 
enclosure. 
terminal, and the Red wire to the 
NETWORK STATUS
POTS 1
POTS 2
TELEPHONE TROUBLESHOOTING
1. Identify the bad line.
2. Disconnect the plug from the appropriate POTS jack and plug
any working telephone into that jack.
If the telephone works, there is a problem inside the house.
If the telephone does not work, contact your service provider.
3. Remove the telephone and replace the plug into the POTS jack.
4. Close the unit.

Figure 22. POTS and Ethernet Connections

RING
 terminal and tighten. 
Two-screw Terminal Bridges
FXS 0/1
TIP
RING
FXS 0/2
TIP
RING
POTS 1
FXS 0/1
FXS 0/2
Ethernet
TIP
RING
POTS 2
TIP
RING
TIP
RING
Connections
ETH 1
ETH 0/1
ETH 2
ETH 0/2
(ETH 1 - data, ETH 2 - video)
TOTAL ACCESS 362 ONT
1187712G1
CLEI
TEL. NUMBER
12V
, 1A
Tie Wrap Point
Installation
TIP
 
35

Advertisement

Table of Contents
loading

Table of Contents