Heat Data Exchange
Note: the "x" in the command value corresponds to the desired zone to be read.
Command Value
(base 10 decimal)
0
1
2
I/O Daughter Board Active Module
3
I/O Daughter Board Active Module
4
I/O Daughter Board Active Module
5
6
7
8
9
A
z000
z001
z002
z003
z004
z005
z006
z007
z008
z009
z00A
z00B
Zone #z Heat Enabled/ Installed State
333587D
E-Flo iQ Heat Data Exchange 18E224
Name
AMZ Active Module Alarms
AMZ Active Module Deviations
AMZ Active Module Advisories
Alarms
Deviations
Advisories
Drum Sizes
Heat Idle Timeout
Line Voltage, Leg #1
Line Voltage, Leg #2
Line Voltage, Leg #3
AMZ Active Zone #z Alarms
AMZ Active Zone #z Deviations
AMZ Active Zone #z Advisories
Zone #z Heat State
Zone #z Actual Temperature
Zone #z Actual Current Usage
Zone #z Actual Duty Cycle
Zone #z Soak Time Remaining
Zone #z Setpoint Temperature
Zone #z Setback Temperature
Zone #z Heat Soak Time
Units/Format
Bitfield
Bitfield
Bitfield
Bitfield
Bitfield
Bitfield
Enum Number:
0: 20 Liters
1: 200 Liters
xx hours
xxx.x Volts
xxx.x Volts
xxx.x Volts
Transition to Zones
Bitfield
Bitfield
Bitfield
Bit Number:
0: Heat Zone Off
1: Heat Zone On
2. Heat Zone Warming up
3. Heat Zone At
Temperature
4. Heat Zone is Heat
Soaking
5. Heat Zone is in Setback
6. Heat Zone has a
Deviation
7. Heat Zone has an Alarm
xx.x deg C
xx.xxx A
xxx.xx %
xx seconds
xx.x deg C
xx.x deg C
xx.x minutes
boolean
Integration
Read/
Min
Max Value
Write
Value
Read
0
2,147,483,647
Read
0
2,147,483,647
Read
0
2,147,483,647
Read
0
2,147,483,647
Read
0
2,147,483,647
Read
0
2,147,483,647
Read/
0
Write
Read/
0
Write
Read
0.0
400.0
Read
0.0
400.0
Read
0.0
400.0
Read
0
2,147,483,647
Read
0
2,147,483,647
Read
0
2,147,483,647
Read
0
127
Read
0
100.0
Read
0.000
25.000
Read
0.00
100.00
Read
0
7200
Read/
15
70.0
Write
Read/
15
70.0
Write
Read/
0
120
Write
Read/
0
Write
1
24
1
83