Graco E-Flo 333587D Operation page 63

Iq dispense system
Table of Contents

Advertisement

Error
Location Type
T3__
AMZ
Advisory
T4J_
Driver
Alarm
T4M_
Driver
Alarm
T4__
AMZ
Alarm
T6__
AMZ
Alarm
T8__
AMZ
Alarm
V1M_
Driver
Alarm
V2H_
AMZ
Deviation
V4M_
Driver
Alarm
333587D
Error
Error Name
Description
High
The zone
Temperature
temperature
H_Z_
has exceeded
the setpoint
High Controls
Temperature of
Temperature P_
the control
board is too hot
High Motor
Temperature of
Temperature P_
the motor is too
hot
High
The zone
Temperature
temperature
H_Z_
has exceeded
the setpoint
Sensor Error
The zone has
H_Z_
no reading from
RTD
No Temperature
The zone
Rise H_Z_
temperature
does not
changed
Low Voltage P_
Supplied bus
voltage is
below
minimum
acceptable limit
Low Voltage H_
The incoming
power is below
minimum
acceptable limit
High Voltage P_
Supplied bus
voltage is
above
maximum
acceptable limit
Cause
Solution
Element continues
Defective RTD. Replace.
to raise above the
setpoint
RTD not in correct
See manual to find correct location of RTD
location on element
on element.
Temperature
Adjust the temp offset errors in the Heat
reading has risen
Setup screen.
too high.
The control board
Ensure ambient temperature is below 120F
temperature inside
(48C).
the driver is too
high
Enclosure fan not
Verify fan in electrical enclosure is spinning.
operating
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
The motor
Ensure ambient temperature is below 120F
temperature inside
(48C).
the driver is too
high
Enclosure fan not
Verify fan in electrical enclosure is spinning.
operating
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
Element continues
Defective RTD. Replace.
to raise above the
setpoint
RTD not in correct
See manual to find correct location of RTD
location on element
on element.
No reading from
Check the wired connections to make sure
the RTD of the heat
that RTD is wired correctly.
zone
Defective RTD. Replace.
The zone
Check fuse on the AMZ that the error
temperature does
element is connected to.
not changed
Check that electrical connector on the
heated hose is plugged into the AMZ.
Defective heater rods in element. Replace.
Transformer faulty
Check output voltage of transformer to
verify it is within acceptable input limits.
Incorrect line
Check line voltage to verify it is as expected
voltage
(230V, 380V, etc.).
Incoming line to
Verify incoming power is correct gauge for
line voltage has
current draw and verify incoming power
dropped below
lines are securely attached to disconnect.
175V
Transformer faulty
Check output voltage of transformer to
verify it is within acceptable input limits.
Incorrect line
Check line voltage to verify it is as expected
voltage
(230V, 380V, etc.).
Troubleshooting
63