Error
Location Type
DD3_
Pump
Alarm or
DD4_
Deviation
(user
selectable)
DKC_
Pump
Alarm
EUD_
Driver
Advisory
EUH_
AMZ
Record
Only
EAL_
ADM
Record
Only
EAUX
ADM
Advisory
EAW_
AMZ
Record
Only
EBUX
ADM
Advisory
EBH_
AMZ
Record
Only
EC0X
ADM
Record
Only
EDF_
AMZ
Record
Only
EDS_
AMZ
Record
Only
333587D
Error
Error Name
Description
Pump Diving P_
Pump diving
detected
Crossover Error
Crossover error
P_
in tandem
system
Auto
The pump has
Depressurization
auto
Occurred
depressurized
Heat Idle
Automatically
Timeout
turns off heat
after the pump
has not moved
for the
designated
amount of time
Access Granted -
Access to
______
locked
screen(s) has
been granted
Download to
Information is
USB In Process
currently being
downloaded to
USB
Heat_ Module
All zones on
Warming Up
heat module
are in warming
up state
Download to
Download to
USB Complete
USB is
complete
Heat_ Module
All zones on
Off
heat module
are turn off
Setup Values
A setting in the
Changed
setup screen
was changed
Heat_ Module
All zones on
Placed into Heat
heat module
Soak
are in heat soak
state
Heat_ Module
All zone on
Placed into
heat module
Setback
are in setback
state
Cause
Solution
Flow to pump inlet
Check inlet valve is open or check inlet
restricted
supply system for clogs.
Second pump is in
Clear the error on the second pump.
error state when
crossover takes
place
The pump was auto
Remember to primary/purge system before
depressurized due
running production.
to the fact that the
pump did not move
for the auto
depressurize timer
All zones on heat
No action necessary.
module were
successfully turned
off
A password has
No action necessary if desired. Else verify
been successfully
settings are correct.
inserted into the
display
Download to USB
No action necessary. Self-clearing.
initiated
All zones on heat
No action necessary.
module were
successfully placed
into warm up
All requested
No action necessary. Self-clearing.
information has
finished
downloading to
USB
All zones on heat
No action necessary.
module were
successfully turned
off
A setting in the
No action necessary if changes were
setup screens was
desired.
changed
All zones on heat
No action necessary.
module were
successfully placed
into heat soak
All zones on heat
No action necessary.
module were
successfully placed
into setback
Troubleshooting
59