Troubleshooting
Error
Location Type
P4C_
Pump
Alarm or
P3C_
Deviation
(user
selectable)
P6D_
Pump
Deviation
P6V_
Pump
Alarm
P6X_
Pump
Alarm
TA__
AMZ
Alarm
T1__
AMZ
Alarm
T2J_
Driver
Deviation
T2__
AMZ
Advisory
T3J_
Driver
Deviation
62
Error
Error Name
Description
High Pressure P_
Measured
outlet pressure
greater than
desired outlet
pressure plus
tolerance
Outlet Pressure
Outlet pressure
Sensor P_
transducer not
connected
Valve Pressure
Valve pressure
Sensor P_
transducer not
connected.
Valve Pressure
Valve pressure
Sensor
transducer not
connected.
Heat Zone Offline
The heat zone
Z_H_
is offline
Low
Temperature of
Temperature
the zone is
H_Z_
below the
setpoint
Motor
Motor
Temperatures
temperature
Sensor P_
thermistor
disconnected
Low
Temperature of
Temperature
the zone is
H_Z_
below the
setpoint
Temperature
Current
Cutback P_
supplied to
motor is being
reduced in
order to lower
driver
temperature
Cause
Solution
Incorrect pressure
Enter correct pressure tolerance percentage
tolerance
in setup screen.
Failed pressure
Check transducer, replace if failed.
transducer
Clog in fluid supply
Check hose and other components in fluid
system
supply system for clogs.
The outlet pressure
Verify outlet pressure transducer is installed
transducer is not
and/or connected correctly. Replace if
connected or faulty
necessary.
The valve pressure
Verify valve pressure transducer is installed
transducer is not
and/or connected properly. Replace if
connected to the
necessary.
driver or faulty
The valve pressure
Verify valve pressure transducer is installed
transducer is not
and/or connected properly. Replace if
connected to the
necessary.
fluid cube or faulty
The AMZ lost
Restore communication.
communication
with the other
Tandem AMZ
Zone has reached
Check resistance of heater rods. Refer to
setpoint but
manual for resistance.
dropped below
setpoint and can
not recover
Adjust the temp offset errors in the Heat
Setup screen.
The motor
Verify motor temperature thermistor is
temperature
installed and/or connected correctly.
thermistor is not
Replace if necessary.
connected or faulty
Zone has reached
Check resistance of heater rods. Refer to
setpoint but
manual for resistance.
dropped below
setpoint and can
not recover
Adjust the temp offset errors in the Heat
Setup screen.
The control board
Ensure ambient temperature is below 120F
temperature inside
(48C). Ensure the enclosure fans are
the driver is too
working properly.
high
Enclosure fan not
Verify fan in electrical enclosure is spinning.
operating
If it is not, disconnect pump from AC power
and check fan wiring or replace fan.
333587D