Graco E-Flo 333587D Operation page 57

Iq dispense system
Table of Contents

Advertisement

Error
Location Type
A8__
AMZ
Alarm
CAC_
ADM
Alarm
CBD_
Driver
Alarm
CBGX
Gateway
Alarm
CBT_
AMZ
Alarm
333587D
Error
Error Name
Description
No Current H_Z_
Power is not
getting to
heating
element
Communication
Communicatio
Error P_
n lost between
ADM and pump
Communication
Communicatio
Error P_
n lost between
pump and ADM
Fieldbus Reset
The fieldbus
has performed
a reset
Communication
Communicatio
Error H_
n lost between
AMZ MZLP4
and ADM
Cause
Solution
Power not getting
Check fuse on the AMZ that the error
to heating element
element is connected to.
Check that electrical connector on the
heated hose is plugged into the AMZ.
Check continuity of pins C and D on
electrical connector at AMZ end of heated
element. See heated element manual for
impedance measurements. Replace hose if
readings are too high.
No 24 VDC power
Reconnect or replace CAN cable
supply to ADM
connecting driver and ADM. If CAN
connection good, check 24V power supply
wiring in driver. Make sure AC power to
pump is turned off before checking power
supply. Yellow LED on driver connector
board should be flashing.
Cross threaded
CAN cables carry 24 V DC power and
CAN cable
communication between modules. A cross
threaded CAN cable connector may cause
problems with communication and/or power
to modules. Carefully check for cross
threaded CAN connections on the ADM and
driver. Yellow LED on driver connector
board should be flashing.
No AC power to
Verify pump is turned on by confirming
driver
disconnect switch is in the ON position.
Yellow LED on driver connector board
should be flashing.
AC disconnect
Disconnect pump from AC power. Check
switch broken
wiring to switch. If wiring is good, replace
the AC disconnect switch.
Ribbon cable
Disconnect pump from AC power. Verify
disconnected
that the ribbon cable inside driver casing is
connected.
Faulty driver
Replace driver control board.
control board
Changing the
No action necessary.
fieldbus setup
properties
No AC power to the
Verify AMZ MZLP4 is turned on by
AMZ MZLP4
confirming disconnect switch of the heat
box is in the ON position.
AC disconnect
Disconnect AMZ MZLP4 from AC power.
switch broken
Check wiring to switch. If wiring is good,
replace the AC disconnect switch of the
heat box.
Faulty AMZ MZLP4
Replace AMZ MZLP4 control board.
control board
Troubleshooting