Graco E-Flo 333587D Operation page 60

Iq dispense system
Table of Contents

Advertisement

Troubleshooting
Error
Location Type
EDT_
AMZ
Record
Only
EKA
Pump
Record
Only
EKM
Pump
Record
Only
EL0X
ADM
Record
Only
EM0X
ADM
Record
Only
EVUX
ADM
Advisory
F1D_
Pump
Alarm or
F2D_
Deviation
(user
selectable)
F3D_
Pump
Alarm or
F4D_
Deviation
(user
selectable)
L1C_
Pump
Alarm
L2C_
Pump
Deviation
60
Error
Error Name
Description
Heat_ Module is
All zone on
at desired
heat module
temperature
are at desired
temperature
Automatic
The system has
Crossover to P_
success
crossover to
the other the
other pump
Manual
The system has
Crossover to P_
received a
crossover
request
Power On
The ADM was
powered on
Power Off
The ADM was
powered off
USB Disabled
USB
downloads/upl
oads are
disabled
Low Flow Rate
Measured flow
P_
rate less than
desired flow
rate minus
tolerance
High Flow Rate
Measured flow
P_
rate greater
than desired
flow rate plus
tolerance
Drum Empty P_
Drum is empty
Drum Empty P_
Drum level is
low
Cause
Solution
All zones on heat
No action necessary if the desired
module have
temperature was reached.
successfully
reached the
desired
temperature
The alarm in the
No action necessary.
system requested a
crossover to the
other pump
The system has
No action necessary.
received a
crossover request
from the ADM or
CGM
The ADM was
No action necessary.
powered on
The ADM was
No action necessary.
powered off
USB
Advisory will clear when drive is removed.
download/upload
Enable USB downloads/uploads in setup
was attempted, but
screen if desired and reinsert USB drive.
USB activity is
disabled within the
setup screen
Fluid supply too
Increase fluid pressure to reach desired
low to achieve
rate.
desired flow rate
Clog in fluid supply
Check hose and other components in fluid
system
supply system for clogs.
No air pressure to
Turn on air to solenoid valves.
solenoid valves
No material supply
Replace drum and prime pump if desired.
Incorrect flow
Enter correct flow tolerance percentage in
tolerance
setup screen.
Incorrect flow
Enter correct flow tolerance percentage in
tolerance
setup screen.
Drum is empty and
Replace drum and prime pump if desired.
needs to be
replaced
Drum level sensor
Verify level sensor is connected. Replace
is disconnected
sensor if connection is good.
Fluid level in drum
Clear deviation and return to normal pump
is low. Consider
operation.
replacing soon
Drum level sensor
Verify level sensor is connected. Replace
is disconnected
sensor if connection is good.
333587D